Fluid Flow - Multi-purpose Fluid Friction Apparatus

 QTS 10

A complete teaching system with comprehensive experiments, data analysis, tutor's and student manuals if desired, and all instruments and controllers.

Investigates the characteristics and operation of valves, orifice meters, venturi meters and variable area flow meters.

  • Studies pressure loss through pipes and fittings
  • Custom designed for the technician/undergraduate teaching
  • Complete visual monitoring
  • Easily operated and used
  • No further development work necessary

Specification

A QVF fluid flow teaching system module designed to study the operation of valves and flow meters and the pressure loss characteristics of pipeline fittings. Incorporating a PVC rough bore pipe and smooth bore pipe, 900 bend, 900 tee, gradual expansion, sudden contraction, 1800 bend, globe valve, ball valve, control valve, diaphragm valve, venturi meter, orifice meter and a variable area flow meter, all manufactured in borosilicate glass. Supplied with a pressure transducer and indicator, interconnecting pipework and supporting structure. Complete with an installation and maintenance manual and tool kit.

Experimental Capabilities

  • Pressure loss through pipeline and fittings
  • Pressure loss/flow rate relationship, through different valve designs
  • Determination of valve constants
  • Relationship between pressure drop and flow through an orifice meter, venturi meter and variable area flowmeter
  • The operation of valves and flow meters

Water is used in all experiments. Other fluids may be used to investigate pressure drop characteristics over wide range of Reynolds numbers.

The experiments are also designed to provide training in chemical process equipment operation.

Optional Manuals

The equipment can be supplied with the following manuals:

Tutor's manual: The basis of a lecture course on valve design, flow measurement and friction in pipeline systems. Also including operating instructions, experiments, typical results and answers to student questions.

Student manuals provide the basics of valve design, flow measurement and friction in pipeline systems and practice with plant operating instructions.

Experiment booklets provide step-by-step instructions for performing the experiments, data to be recorded and questions to be answered.

Additional copies of the student manuals and experiment booklets can be reordered.

Description

The equipment consists of three test circuits fixed to a free-standing, plastic coated backboard housing the pressure tapping selection valves, digital pressure indicator, pressure transducer and variable area flowmeter. The fluid flowrate through each circuit is controlled by a flow control valve and measured by the variable area flowmeter.

Each circuit can be tested individually by means of isolation valves. The pressure at each point in the circuit is given by the digital pressure meter and simply selected by means of multiport selection valves.

The equipment is designed for direct connection to the main water supply or an optional recirculation pump can be supplied.

Circuit one contains a length of smooth and rough bore pipe and various pipeline fittings to allow determination of pressure loss at various flowrates.

Circuit two contains four valves and allows the pressure loss, operating characteristics and the valve constant for each valve design to be determined.

Circuit three contains a venturi meter and orifice meter and, together with the variable area flow area, allows the relationship between pressure loss and flow to be investigated.

Note

This unit is supplied pre-assembled. A mimic diagram, fixed to the backboard, ensures simple identification of components.

Options

Either steam or electric heating.

Electrical System

The electrical system can be designed to meet your local requirements.

Equipment Specification

  • Smooth bore pipe
  • Rough bore pipe
  • 900 bend
  • 900 elbow
  • Gradual expansion
  • Sudden contraction
  • 1800 bend
  • Globe valve
  • Diaphragm valve
  • Ball valve
  • Control valve
  • Orifice meter
  • Venturi meter
  • Variable area flowmeter
  • Recirculation pump (1 kW 220/240V single phase 60Hz)

Installation and maintenance manual provides detailed instructions on installing and maintaining the plant.

Instrumentation

0-1000 millibar digital pressure indicator and transducer

Utilities Requirements

Water: 100 L/min at 1 bar g

Space Requirements

(height x floor area)
2.3 x 2.5 1.0 meters