Are there any specific operating methods that make reactors more susceptible to wear and tear?

Running the agitator blades through the liquid level, which causes skipping and can lead to cavitation, is one of the most common practices performed while operating glass lined equipment. If this is a necessary practice then reducing the agitator speed by 50% will lessen the risk for damage occurring.